Journal article
Young's double-slit interference with single hard X-ray photons
TE Gureyev, CJ Hall, B Arhatari, D Pelliccia, A Aminzadeh, KM Pavlov, HM Quiney
Optics Express | Optica Publishing Group | Published : 2024
DOI: 10.1364/OE.521892
Open access
Abstract
Double-slit interference experiments using monochromatic hard X-rays with the energy of 25 keV are presented. The experiments were performed at a synchrotron source with a distance of 110 m between the interferometer and the detector to produce an interference pattern with a sufficiently broad period that could be adequately sampled by a photon-counting detector with 75 micrometre pixels. In the single-particle version of the experiment, over one million image frames with a single registered photon in each one were collected. The sum of these frames showed a clear presence of the interference pattern with the expected period. Subsequent analysis provided an objective estimation of the minima..
View full abstractRelated Projects (1)
Grants
Awarded by Australian Nuclear Science and Technology Organisation
Awarded by National Health and Medical Research Council
Funding Acknowledgements
Funding. Australian Nuclear Science and Technology Organisation (AS233/IMBL/20286) ; National Health and Medical Research Council (APP2011204) .